APC AP8853 power distribution unit (PDU) 42 AC outlet(s) 0U Black

APC AP8853. PDU types: Metered, Rack capacity: 0U, Type: Single-phase. AC outlets quantity: 42 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, Power plug: IEC309. Cable length: 118.1" (3 m), Certification: RoHS, REACH IEC 60950,VDE. Monitoring: Current, Power, Voltage. AC input frequency: 50 - 60 Hz, Nominal output voltage: 230 V, Load capacity: 7680 VA
Manufacturer: APC
SKU: 2750180
Manufacturer part number: AP8853
Vendor: Synnex
MSRP: $1,390.00
$943.91
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
Products specifications
Attribute nameAttribute value
Weight15.3 lbs
MountingVertical
TypeSingle-phase
Load Capacity7680 VA
Rack capacity0U
AC outlets quantity42 AC outlet(s)
CertificationRoHS, REACH IEC 60950,VDE
Storage temperature (T-T)-25 - 65 °C
Dimensions (WxDxH)2.2 x 1.73 x 70.5"
PDU typesMetered
Output connections36x IEC 320 C13 6x IEC 320 C19
Input connection typeIEC 309 32A 2P+E
Power plugIEC309
Maximum input current per phase32 A
Maximum total current draw per phase32 A
Maximum power7680 W
MonitoringCurrent, Power, Voltage
Cable Length118.1"
Product colorBlack
AC outlet typesC13 coupler, C19 coupler
Operating temperature (T-T)5 - 45 °C
Operating relative humidity (H-H)5 - 95 %
Storage relative humidity (H-H)5 - 95 %
Nominal output voltage230 V
AC input frequency50 - 60 Hz
*
*
*
Products specifications
Attribute nameAttribute value
Weight15.3 lbs
MountingVertical
TypeSingle-phase
Load Capacity7680 VA
Rack capacity0U
AC outlets quantity42 AC outlet(s)
CertificationRoHS, REACH IEC 60950,VDE
Storage temperature (T-T)-25 - 65 °C
Dimensions (WxDxH)2.2 x 1.73 x 70.5"
PDU typesMetered
Output connections36x IEC 320 C13 6x IEC 320 C19
Input connection typeIEC 309 32A 2P+E
Power plugIEC309
Maximum input current per phase32 A
Maximum total current draw per phase32 A
Maximum power7680 W
MonitoringCurrent, Power, Voltage
Cable Length118.1"
Product colorBlack
AC outlet typesC13 coupler, C19 coupler
Operating temperature (T-T)5 - 45 °C
Operating relative humidity (H-H)5 - 95 %
Storage relative humidity (H-H)5 - 95 %
Nominal output voltage230 V
AC input frequency50 - 60 Hz