APC AP8881 power distribution unit (PDU) 42 AC outlet(s) 0U Black

APC AP8881. PDU types: Metered, Rack capacity: 0U, Mounting: Vertical. AC outlets quantity: 42 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, Power plug: IEC309. Cable length: 72" (1.83 m), Certification: CSA C22.2 No. 60950,IEC 60950,UL 60950-1,VDE RoHS, REACH. Monitoring: Current, Power, Voltage. Nominal input voltage: 400 V, Maximum current: 16 A, AC input frequency: 50 - 60 Hz
Manufacturer: APC
SKU: 2858544
Manufacturer part number: AP8881
Vendor: Synnex
MSRP: $2,115.00
$1,438.54
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
Products specifications
Attribute nameAttribute value
Weight14.1 lbs
MountingVertical
Load Capacity11040 VA
Rack capacity0U
AC outlets quantity42 AC outlet(s)
Maximum current16 A
CertificationCSA C22.2 No. 60950,IEC 60950,UL 60950-1,VDE RoHS, REACH
Storage temperature (T-T)-25 - 65 °C
Nominal input voltage400 V
Dimensions (WxDxH)2.2 x 1.73 x 70.5"
PDU typesMetered
Output connections36x IEC 320 C13 6x IEC 320 C19
Input connection typeIEC 309 16A 3P+N+PE, IEC 309 20A 3P+N+E
Power plugIEC309
Maximum input current per phase16 A
Maximum total current draw per phase16 A
Maximum power11040 W
MonitoringCurrent, Power, Voltage
Cable Length72"
Product colorBlack
AC outlet typesC13 coupler, C19 coupler
Operating temperature (T-T)5 - 45 °C
Operating relative humidity (H-H)5 - 95 %
Storage relative humidity (H-H)5 - 95 %
Nominal output voltage230 V
AC input frequency50 - 60 Hz
*
*
*
Products specifications
Attribute nameAttribute value
Weight14.1 lbs
MountingVertical
Load Capacity11040 VA
Rack capacity0U
AC outlets quantity42 AC outlet(s)
Maximum current16 A
CertificationCSA C22.2 No. 60950,IEC 60950,UL 60950-1,VDE RoHS, REACH
Storage temperature (T-T)-25 - 65 °C
Nominal input voltage400 V
Dimensions (WxDxH)2.2 x 1.73 x 70.5"
PDU typesMetered
Output connections36x IEC 320 C13 6x IEC 320 C19
Input connection typeIEC 309 16A 3P+N+PE, IEC 309 20A 3P+N+E
Power plugIEC309
Maximum input current per phase16 A
Maximum total current draw per phase16 A
Maximum power11040 W
MonitoringCurrent, Power, Voltage
Cable Length72"
Product colorBlack
AC outlet typesC13 coupler, C19 coupler
Operating temperature (T-T)5 - 45 °C
Operating relative humidity (H-H)5 - 95 %
Storage relative humidity (H-H)5 - 95 %
Nominal output voltage230 V
AC input frequency50 - 60 Hz