APC Symmetra LX 4kVA 3200 W

APC Symmetra LX 4kVA. Output power capacity: 4 kVA, Output power: 3200 W. Battery technology: Sealed Lead Acid (VRLA), Battery recharge time: 3 h. Certification: CSA,FCC Part 15 Class A,UL 1778. Weight: 295.6 lbs (134.1 kg). Battery type: SYBT5, Interface: DB-9 RS-232,Smart-Slot, Output connections: 1x Hard Wire 4-wire (2PH + N +G) 2x NEMA L14-30R 4x NEMA L5-20R
Manufacturer: APC
SKU: 1003432
Manufacturer part number: SYA4K8RMP
Vendor: Synnex
MSRP: $16,405.00
$11,193.24
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Modular design Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules. Configurable for N+1 internal redundancy Provides high availabilty through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load. Redundant Intelligence Modules Provides higher availability to the UPS connected loads by giving redundant communication paths to critical UPS functions. Hot-swappable intelligence modules Ensures clean, uninterrupted power to protected equipment during Intelligence Module replacement. Hot-swappable power modules Ensures clean, uninterrupted power to protected equipment during Power Module replacement. Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced Power Modules connected in parallel Enhances availability by allowing immediate, seamless recovery from isolated module failures. Battery modules connected in parallel Delivers higher availability through redundant batteries. Automatic internal bypass Supplies utility power to the connected loads in the event of a UPS overload condition or fault. Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power.
Modular design Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules. Configurable for N+1 internal redundancy Provides high availabilty through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load. Redundant Intelligence Modules Provides higher availability to the UPS connected loads by giving redundant communication paths to critical UPS functions. Hot-swappable intelligence modules Ensures clean, uninterrupted power to protected equipment during Intelligence Module replacement. Hot-swappable power modules Ensures clean, uninterrupted power to protected equipment during Power Module replacement. Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced Power Modules connected in parallel Enhances availability by allowing immediate, seamless recovery from isolated module failures. Battery modules connected in parallel Delivers higher availability through redundant batteries. Automatic internal bypass Supplies utility power to the connected loads in the event of a UPS overload condition or fault. Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power.
Products specifications
Attribute nameAttribute value
Weight295.6 lbs
Battery TypeSYBT5
CertificationCSA,FCC Part 15 Class A,UL 1778
Nominal input voltage208 V
Dimensions (WxDxH)18.6 x 27.1 x 22.5"
InterfaceDB-9 RS-232,Smart-Slot
Output power capacity4 kVA
Output connections1x Hard Wire 4-wire (2PH + N +G) 2x NEMA L14-30R 4x NEMA L5-20R
Output power3200 W
Input connection typeHard Wire 4-wire (2PH+N+G)
Battery Recharge Time3 h
Emergency Power Off (EPO)Y
Operating temperature (T-T)0 - 40 °C
Storage temperature (T-T)-15 - 45 °C
Operating relative humidity (H-H)0 - 95 %
Storage relative humidity (H-H)0 - 95 %
Audible alarm(s)Y
Battery technologySealed Lead Acid (VRLA)
Hot-swap batteryY
*
*
*
Products specifications
Attribute nameAttribute value
Weight295.6 lbs
Battery TypeSYBT5
CertificationCSA,FCC Part 15 Class A,UL 1778
Nominal input voltage208 V
Dimensions (WxDxH)18.6 x 27.1 x 22.5"
InterfaceDB-9 RS-232,Smart-Slot
Output power capacity4 kVA
Output connections1x Hard Wire 4-wire (2PH + N +G) 2x NEMA L14-30R 4x NEMA L5-20R
Output power3200 W
Input connection typeHard Wire 4-wire (2PH+N+G)
Battery Recharge Time3 h
Emergency Power Off (EPO)Y
Operating temperature (T-T)0 - 40 °C
Storage temperature (T-T)-15 - 45 °C
Operating relative humidity (H-H)0 - 95 %
Storage relative humidity (H-H)0 - 95 %
Audible alarm(s)Y
Battery technologySealed Lead Acid (VRLA)
Hot-swap batteryY