Tripp Lite IS500HG surge protector White 4 AC outlet(s) 120 V 120.1" (3.05 m)

Tripp Lite IS500HG. Surge energy rating: 680 J, AC outlets quantity: 4 AC outlet(s), AC outlet types: NEMA 5–15R. Power plug: NEMA 5–15P. Product color: White, EMI/RFI noise filtering: 65 dB, Country of origin: Taiwan. Cable length: 120.1" (3.05 m), Weight: 22.3 lbs (10.1 kg), Width: 6.25" (158.8 mm). Package width: 9" (228.6 mm), Package depth: 11.4" (289.6 mm), Package height: 8.3" (210.8 mm)
Manufacturer: Tripp Lite
SKU: 303937
Manufacturer part number: IS500HG
Vendor: Synnex
MSRP: $538.00
$382.02
PRICE BREAKS - The more you buy, the more you save
Quantity2+
Price$382.02
This product has a minimum quantity of 2
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Isolator Series UL60601-1 Listed Medical Grade Isolation Transformers offer line isolation, continuous noise filtering and enhanced common mode surge suppression. An internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL60601-1 medical-grade listing with hospital-grade plug and outlet receptacles makes Isolator medical-grade transformers ideal for protection of sensitive electronic equipment in patient-care areas. Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels less than 100 microamps. Secondary neutral-to-ground bonding virtually eliminates common mode noise, providing an isolated neutral-ground reference for sensitive equipment, and an inexpensive alternative to dedicated circuits and site electrical upgrades. Removes EMI/RFI noise, utility switching transients and harmonics generated by other on-site loads and utility or lightning related surge conditions. Active transformer filtering provides continuous common-mode noise rejection with no wearable parts. Unique ability to reduce surges in the worst of power environments to harmless levels. Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode. Model IS500HG includes 4 widely spaced NEMA 5-15R hospital-grade output receptacles, a 10-ft. power cord, hospital-grade input plug, circuit breaker overload protection, and lighted power switch. Rugged all-metal unit ships ready for placement in any industrial, medical, office or network environment. PLUG/OUTLETS: Input - NEMA 5-15P Hospital Grade; Output - 4 NEMA 5-15R Hospital Grade ELECTRICAL: 120V AC, 60Hz, 2.1A (Requires NEMA 5-15R wall receptacle) - The IS500HG Medical Grade Isolation Transformer offers line isolation and continuous noise filtering - Internal low-impedance isolation transformer with Faraday shield offers 100% isolation from the input AC line - Full UL60601-1 medical-grade listing with hospital-grade plug and outlet receptacles makes Isolator Hospital Grade transformers ideal for the protection of - sensitive electronic equipment in patient-care areas. - Reduces the cumulative leakage current of the Isolator and connected equipment to levels less than 100 microamps. - Secondary neutral-to-ground bonding eliminates common mode noise, providing an isolated ground reference for sensitive equipment - Serves as an inexpensive alternative to dedicated circuits and site electrical upgrades - Removes EMI/RFI noise, utility switching transients, load-generated harmonics and ground loops - Active transformer filtering offers continuous common-mode noise rejection with no wearable parts; unique ability to reduce surges in the worst of power - environments to harmless levels - Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode - Includes 4 widely spaced NEMA 5-15R hospital-grade output receptacles, a 10-ft. power cord, hospital-grade input plug, circuit breaker overload - protection and lighted power switch. - Rugged all-metal unit housing; ships ready for upright tower placement in any industrial, medical, office or network environment
Isolator Series UL60601-1 Listed Medical Grade Isolation Transformers offer line isolation, continuous noise filtering and enhanced common mode surge suppression. An internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL60601-1 medical-grade listing with hospital-grade plug and outlet receptacles makes Isolator medical-grade transformers ideal for protection of sensitive electronic equipment in patient-care areas. Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels less than 100 microamps. Secondary neutral-to-ground bonding virtually eliminates common mode noise, providing an isolated neutral-ground reference for sensitive equipment, and an inexpensive alternative to dedicated circuits and site electrical upgrades. Removes EMI/RFI noise, utility switching transients and harmonics generated by other on-site loads and utility or lightning related surge conditions. Active transformer filtering provides continuous common-mode noise rejection with no wearable parts. Unique ability to reduce surges in the worst of power environments to harmless levels. Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode. Model IS500HG includes 4 widely spaced NEMA 5-15R hospital-grade output receptacles, a 10-ft. power cord, hospital-grade input plug, circuit breaker overload protection, and lighted power switch. Rugged all-metal unit ships ready for placement in any industrial, medical, office or network environment. PLUG/OUTLETS: Input - NEMA 5-15P Hospital Grade; Output - 4 NEMA 5-15R Hospital Grade ELECTRICAL: 120V AC, 60Hz, 2.1A (Requires NEMA 5-15R wall receptacle) - The IS500HG Medical Grade Isolation Transformer offers line isolation and continuous noise filtering - Internal low-impedance isolation transformer with Faraday shield offers 100% isolation from the input AC line - Full UL60601-1 medical-grade listing with hospital-grade plug and outlet receptacles makes Isolator Hospital Grade transformers ideal for the protection of - sensitive electronic equipment in patient-care areas. - Reduces the cumulative leakage current of the Isolator and connected equipment to levels less than 100 microamps. - Secondary neutral-to-ground bonding eliminates common mode noise, providing an isolated ground reference for sensitive equipment - Serves as an inexpensive alternative to dedicated circuits and site electrical upgrades - Removes EMI/RFI noise, utility switching transients, load-generated harmonics and ground loops - Active transformer filtering offers continuous common-mode noise rejection with no wearable parts; unique ability to reduce surges in the worst of power - environments to harmless levels - Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode - Includes 4 widely spaced NEMA 5-15R hospital-grade output receptacles, a 10-ft. power cord, hospital-grade input plug, circuit breaker overload - protection and lighted power switch. - Rugged all-metal unit housing; ships ready for upright tower placement in any industrial, medical, office or network environment
Products specifications
Attribute nameAttribute value
Weight22.3 lbs
Capacity500 W
Package width9"
Package depth11.4"
Package height8.3"
Dimensions (WxDxH)6.25 x 9.25 x 5.75"
Surge energy rating680 J
Master (outer) case GTIN (EAN/UPC)10037332115895
Master (outer) case weight46.5 lbs
Master (outer) case width11.8"
Master (outer) case height9.6"
EMI/RFI noise filtering65 dB
Nominal current output4.2 A
Cable Length120.1"
*
*
*
Products specifications
Attribute nameAttribute value
Weight22.3 lbs
Capacity500 W
Package width9"
Package depth11.4"
Package height8.3"
Dimensions (WxDxH)6.25 x 9.25 x 5.75"
Surge energy rating680 J
Master (outer) case GTIN (EAN/UPC)10037332115895
Master (outer) case weight46.5 lbs
Master (outer) case width11.8"
Master (outer) case height9.6"
EMI/RFI noise filtering65 dB
Nominal current output4.2 A
Cable Length120.1"