Tripp Lite PDUMH30ATNET power distribution unit (PDU) 25 AC outlet(s) 2U Black

Tripp Lite PDUMH30ATNET. PDU types: Switched, Rack capacity: 2U, Mounting: Horizontal. AC outlets quantity: 25 AC outlet(s), AC outlet types: NEMA 5–15,NEMA 5–20R,NEMA L5-30R, Power plug: NEMA L5-30P. Cable length: 118.1" (3 m), Certification: UL 60950-1 (USA), CSA (Canada), Class A (Emissions), NOM (Mexico). Nominal input voltage: 100-127 V, Maximum current: 30 A, AC input frequency: 60 Hz. Width: 17.3" (439.9 mm), Depth: 11.9" (302 mm), Dimensions (WxDxH): 17.3 x 17.3 x 3.39" (439 x 439 x 86 mm)
Manufacturer: Tripp Lite
SKU: 3016124
Manufacturer part number: PDUMH30ATNET
Vendor: Synnex
MSRP: $1,761.56
$1,038.63
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Tripp Lite Switched ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Highly reliable solid-state switching between primary and secondary inputs occurs in 1-5 milliseconds. Switched PDU features include individually controllable output receptacles and built-in network interface. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability. - 120V 30A Power Distribution Unit (PDU) with Auto-Transfer Switch (ATS) and Switched outlets (Agency de-rated to 24A) - ATS features provide redundant power for critical network equipment with a single input power cord - Switched PDU features enable programmable or real-time power control of individual outlets via built-in network interface - Visual meter reports output amp and kW power consumption, plus voltage and temperature/humidity data with optional ENVIROSENSE sensor - 25 switched outlets (24 5-15/20R & 1 L5-30R) - 2U horizontal rackmount form factor; 11.9 in. / 30.2cm depth - Set of two 10 ft. / 3m NEMA L5-30P input line cords enable separate PRIMARY and SECONDARY input connections - ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails or becomes unstable, the ATS will switch to maintain output sourced from the secondary input cable until power on the primary input is restored and stable - Highly reliable solid-state switching enables fast 1-5 millisecond trasfer between primary and secondary inputs - ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system (in a two-UPS environment, the primary input cable must be supported by an online UPS with zero transfer time similar to Tripp Lite SmartOnline series) - Advanced ATS configurations utilizing separate mains circuits, backup generators and even separate out of phase utility power grid feeds are fully supported - On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower quality than the primary source - DHCP/Manual configuration support; Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocols - Compatible with optional ENVIROSENSE temperature monitor - Outlets are factory programmed for sequential turn-on at 250 millisecond intervals as the PDU is first energized - Front panel LEDs confirm power availability on both input lines - TAA Compliant Version Available - Order Tripp Lite PDUMH30ATNETAA
Tripp Lite Switched ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Highly reliable solid-state switching between primary and secondary inputs occurs in 1-5 milliseconds. Switched PDU features include individually controllable output receptacles and built-in network interface. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability. - 120V 30A Power Distribution Unit (PDU) with Auto-Transfer Switch (ATS) and Switched outlets (Agency de-rated to 24A) - ATS features provide redundant power for critical network equipment with a single input power cord - Switched PDU features enable programmable or real-time power control of individual outlets via built-in network interface - Visual meter reports output amp and kW power consumption, plus voltage and temperature/humidity data with optional ENVIROSENSE sensor - 25 switched outlets (24 5-15/20R & 1 L5-30R) - 2U horizontal rackmount form factor; 11.9 in. / 30.2cm depth - Set of two 10 ft. / 3m NEMA L5-30P input line cords enable separate PRIMARY and SECONDARY input connections - ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails or becomes unstable, the ATS will switch to maintain output sourced from the secondary input cable until power on the primary input is restored and stable - Highly reliable solid-state switching enables fast 1-5 millisecond trasfer between primary and secondary inputs - ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system (in a two-UPS environment, the primary input cable must be supported by an online UPS with zero transfer time similar to Tripp Lite SmartOnline series) - Advanced ATS configurations utilizing separate mains circuits, backup generators and even separate out of phase utility power grid feeds are fully supported - On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower quality than the primary source - DHCP/Manual configuration support; Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocols - Compatible with optional ENVIROSENSE temperature monitor - Outlets are factory programmed for sequential turn-on at 250 millisecond intervals as the PDU is first energized - Front panel LEDs confirm power availability on both input lines - TAA Compliant Version Available - Order Tripp Lite PDUMH30ATNETAA
Products specifications
Attribute nameAttribute value
Height3.41"
Weight15.3 lbs
MountingHorizontal
Package width16.7"
Package depth19.7"
Package height7.7"
Package weight19.5 lbs
AC outlets quantity25 AC outlet(s)
AC outlet typesNEMA 5–15,NEMA 5–20R,NEMA L5-30R
CertificationUL 60950-1 (USA), CSA (Canada), Class A (Emissions), NOM (Mexico)
Nominal input voltage100-127 V
Dimensions (WxDxH)17.3 x 17.3 x 3.39"
PDU typesSwitched
Nominal output voltage100-127 V
Country of OriginTaiwan
Width17.3"
Depth11.9"
Housing MaterialMetal
Cable Length118.1"
Product colorBlack
Sustainability certificatesRoHS
Rack capacity2U
Maximum current30 A
Quantity per master (outer) case1 pc(s)
Storage temperature (T-T)-15 - 50 °C
LED indicatorsY
Operating altitude0 - 118110.2"
AC input frequency60 Hz
Power plugNEMA L5-30P
*
*
*
Products specifications
Attribute nameAttribute value
Height3.41"
Weight15.3 lbs
MountingHorizontal
Package width16.7"
Package depth19.7"
Package height7.7"
Package weight19.5 lbs
AC outlets quantity25 AC outlet(s)
AC outlet typesNEMA 5–15,NEMA 5–20R,NEMA L5-30R
CertificationUL 60950-1 (USA), CSA (Canada), Class A (Emissions), NOM (Mexico)
Nominal input voltage100-127 V
Dimensions (WxDxH)17.3 x 17.3 x 3.39"
PDU typesSwitched
Nominal output voltage100-127 V
Country of OriginTaiwan
Width17.3"
Depth11.9"
Housing MaterialMetal
Cable Length118.1"
Product colorBlack
Sustainability certificatesRoHS
Rack capacity2U
Maximum current30 A
Quantity per master (outer) case1 pc(s)
Storage temperature (T-T)-15 - 50 °C
LED indicatorsY
Operating altitude0 - 118110.2"
AC input frequency60 Hz
Power plugNEMA L5-30P