Tripp Lite PDUMH30HV19NET. PDU types: Switched, Rack capacity: 2U, Mounting: Horizontal. AC outlets quantity: 14 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, Power plug: NEMA L6-30P. Cable length: 179.9" (4.57 m), Certification: UL 60950-1 (USA), CSA (Canada), Class A (Emissions), NOM (Mexico). Nominal input voltage: 200-240 V, Maximum current: 30 A, AC input frequency: 50 - 60 Hz. Width: 17.5" (444.5 mm), Depth: 12.5" (317.5 mm), Dimensions (WxDxH): 17.5 x 12.5 x 3.5" (445 x 317.5 x 89 mm)
Manufacturer: Tripp Lite
SKU: 2716165
Manufacturer part number: PDUMH30HV19NET
Vendor: Synnex
MSRP: $1,331.00
$784.77
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Tripp Lite single phase Switched PDU / Power Distribution Unit offers advanced network control and monitoring with the ability to turn on, turn off, recycle or lock-out power to each individual receptacle, monitor site electrical conditions and remotely monitor output power consumption. PowerAlert interface supports remote control and custom notification of user-specified conditions via email, secure web, SNMP, Telnet or SSH interface. Individually switched outlets can be controlled in real-time to remotely reboot unresponsive network hardware, or be custom programmed for user-defined power-up and power-down sequences to ensure proper startup of interdependent IT systems and prevent inrush-related overloads as network equipment is first energized. Unused PDU outlets can be electronically locked off to prevent the connection of unauthorized hardware. PDU output current consumption in amps is continuously displayed locally via visual meter and remotely via web/network interface to warn of potential overloads before critical IT mains or branch breakers trip. - 30A 208/240V Switched Power Distribution Unit / PDU with built-in web/network interface (Agency derated to 24A continuous) - Attached L6-30P 208/240V single phase input, 15 ft. / 4.6m input cord - 2U horizontal rackmount form factor - 14 switched outlets (8 C13, 6 C19) - Supports power-on, power-off or reboot of each outlet on a real-time or programmable basis - Enables reboot of locked equipment, custom power-on/power-off sequences, load-shedding of optional loads and disabling unused outlets - Network interface provides PDU control and data regarding input voltage and total output load level in amps - Digital display continuously reports output load in amps in 3 segments (load bank 1, load bank 2, total) - Supports user-specified alarm notification thresholds - In-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4 optional SRSWITCH door sensors - DHCP/Manual configuration support - 10/100 Mbps auto-sensing - Real-time clock backup maintains the time of day and date even if the PDU is unpowered - Tiered access privileges allow an administrator and a guest to login via web browser - Alert notifications via email or SNMP traps offer immediate event notification - Firmware upgrade ability supports future product enhancements - Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocols - Fully compatible with FREE PowerAlert Network Management System / NMS Software - Mounting flanges support installation in 2 and 4 post racks, with additional support for wall-mount and under-counter installation formats - Mounting ears are reversible for front or rear facing rackmount installation - Included cord retention brackets - TAA Compliant Version Available - Order Tripp Lite PDUMH30HV19NTAA
Tripp Lite single phase Switched PDU / Power Distribution Unit offers advanced network control and monitoring with the ability to turn on, turn off, recycle or lock-out power to each individual receptacle, monitor site electrical conditions and remotely monitor output power consumption. PowerAlert interface supports remote control and custom notification of user-specified conditions via email, secure web, SNMP, Telnet or SSH interface. Individually switched outlets can be controlled in real-time to remotely reboot unresponsive network hardware, or be custom programmed for user-defined power-up and power-down sequences to ensure proper startup of interdependent IT systems and prevent inrush-related overloads as network equipment is first energized. Unused PDU outlets can be electronically locked off to prevent the connection of unauthorized hardware. PDU output current consumption in amps is continuously displayed locally via visual meter and remotely via web/network interface to warn of potential overloads before critical IT mains or branch breakers trip. - 30A 208/240V Switched Power Distribution Unit / PDU with built-in web/network interface (Agency derated to 24A continuous) - Attached L6-30P 208/240V single phase input, 15 ft. / 4.6m input cord - 2U horizontal rackmount form factor - 14 switched outlets (8 C13, 6 C19) - Supports power-on, power-off or reboot of each outlet on a real-time or programmable basis - Enables reboot of locked equipment, custom power-on/power-off sequences, load-shedding of optional loads and disabling unused outlets - Network interface provides PDU control and data regarding input voltage and total output load level in amps - Digital display continuously reports output load in amps in 3 segments (load bank 1, load bank 2, total) - Supports user-specified alarm notification thresholds - In-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4 optional SRSWITCH door sensors - DHCP/Manual configuration support - 10/100 Mbps auto-sensing - Real-time clock backup maintains the time of day and date even if the PDU is unpowered - Tiered access privileges allow an administrator and a guest to login via web browser - Alert notifications via email or SNMP traps offer immediate event notification - Firmware upgrade ability supports future product enhancements - Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocols - Fully compatible with FREE PowerAlert Network Management System / NMS Software - Mounting flanges support installation in 2 and 4 post racks, with additional support for wall-mount and under-counter installation formats - Mounting ears are reversible for front or rear facing rackmount installation - Included cord retention brackets - TAA Compliant Version Available - Order Tripp Lite PDUMH30HV19NTAA
Products specifications
Attribute nameAttribute value
Weight13.8 lbs
MountingHorizontal
Package width16.9"
Package height7.8"
Package weight17.8 lbs
AC outlets quantity14 AC outlet(s)
CertificationUL 60950-1 (USA), CSA (Canada), Class A (Emissions), NOM (Mexico)
Nominal input voltage200-240 V
Dimensions (WxDxH)17.5 x 12.5 x 3.5"
PDU typesSwitched
Nominal output voltage200-240 V
Country of OriginTaiwan
Width17.5"
Depth12.5"
Height3.5"
Housing MaterialMetal
Cable Length179.9"
Product colorBlack
Package depth20"
Sustainability certificatesRoHS
Rack capacity2U
AC outlet typesC13 coupler, C19 coupler
Maximum current30 A
Quantity per master (outer) case1 pc(s)
Storage temperature (T-T)-15 - 50 °C
LED indicatorsY
Operating altitude0 - 118110.2"
AC input frequency50 - 60 Hz
Power plugNEMA L6-30P
*
*
*
Products specifications
Attribute nameAttribute value
Weight13.8 lbs
MountingHorizontal
Package width16.9"
Package height7.8"
Package weight17.8 lbs
AC outlets quantity14 AC outlet(s)
CertificationUL 60950-1 (USA), CSA (Canada), Class A (Emissions), NOM (Mexico)
Nominal input voltage200-240 V
Dimensions (WxDxH)17.5 x 12.5 x 3.5"
PDU typesSwitched
Nominal output voltage200-240 V
Country of OriginTaiwan
Width17.5"
Depth12.5"
Height3.5"
Housing MaterialMetal
Cable Length179.9"
Product colorBlack
Package depth20"
Sustainability certificatesRoHS
Rack capacity2U
AC outlet typesC13 coupler, C19 coupler
Maximum current30 A
Quantity per master (outer) case1 pc(s)
Storage temperature (T-T)-15 - 50 °C
LED indicatorsY
Operating altitude0 - 118110.2"
AC input frequency50 - 60 Hz
Power plugNEMA L6-30P